2524
Option 3
Vertical balanced flue system with two 90º bends
Flue components required
Flue Diameter Description Quantity Worcester Part No.
30CDi Conventional
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 7 7 719 002 349
100mm 90º Bend 2 7 719 002 348
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 16 7 719 001 892
125mm 90º Bend 2 7 719 001 891
40CDi Conventional
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 13 7 719 001 892
125mm 90º Bend 2 7 719 001 891
30CDi System
100mm Vertical Flue Kit 1 7 719 002 430
100mm Flue Extension up to 7 7 719 002 349
100mm 90º Bend 2 7 719 002 348
125mm Vertical Flue Kit 1 7 719 002 431
125mm Flue Extension up to 16 7 719 001 892
125mm 90º Bend 2 7 719 001 891
Maximum total straight flue length
(inc. terminal) 100mm dia 125mm dia
30CDi Conventional 5,400mm 14,500mm
40CDi Conventional N/A 12,000mm
30CDi System 5,400mm 14,500mm
Plume management system options
Plume management system
Standard plume management system
The flue terminal outlet has built-in stops to limit rotation
for horizontal fluing to allow condensate to run back into
the boiler for safe disposal. Do not attempt to force beyond
the limit stops.
All plume management sections must rise by at least
173mm per metre (10º) from the terminal to ensure that
condensate flows back into the boiler.
500mm (M)
Opening in building
e.g. window
Direction of
flue discharge
Min. 1,500mm
Opening in building
e.g. window
Direction of
flue discharge
Min. 1,500mm
Re-directing flue discharge from a 60mm dia plume
management outlet
Condensfit II telescopic flue and plume management
system measuring
500mm
(min) (M)
L (max)
4,500mm
(max) (M)
L (max)
Effective straight flue lengths for telescopic flue with
plume management
Model Fig. A Fig. B
Max. straight flue Max. straight flue
length (L) with min. length (L) with max.
plume management plume management
length (M)* (mm) length (M)* (mm)
30CDi Conventional** 5,450 2,650
40CDi Conventional** 600 N/A
30CDi System** 5,450 2,650
NOTE:
Plume management minimum straight length = 500mm
Plume management maximum straight length = 4,500mm
**For every additional 1,000mm of plume management
length (M), reduce flue length (L) by 700mm – see figures
A and B.
Fig A
Fig B
BBT1253 G_CDi Rg+Sys TS c08_07 25/6/07 09:21 Page 24