Greenstar 30CDi System
condensing boiler – inside story
Installing the Greenstar CDi
regular and system boiler series
The Greenstar CDi range is designed for connection to a traditional
heating and hot water system. The major benefits of the Greenstar
CDi regular or system boilers are:
The boiler is compatible with S and Y plan systems
The boiler comes supplied with a wall mounting bracket
WB5 cast aluminium/silicon heat cell
A syphonic condensate trap is pre-plumbed within
Built-in pump and expansion vessel*
No feed and expansion cistern in the loft space*
Less pipe work*
*30CDi System boiler
960mm
450mm
Using 100mm flue kit
- 1,112mm
Using 125mm flue kit
- 1,152mm
1. Aluminium/Silicon WB5 Heat Exchanger
2. Pre-mix Fan
3. Down Firing Low Nox Burner
4. Gas Valve
5. Syphon
6. On/Off Button
7. Temperature Control
8. Digital Display
9. Auto Air Vent
10. Drain Point
11. Air/Gas Adjustment Screw
12. Expansion Vessel
13. Modulating Pump
14. Plug-in Control
Key to components
Siting of appliance
General
The appliances are not suitable for external installation.
The wall on which the boiler is to be mounted should be capable of
supporting an overall weight of approximately 50kg.
The wall does not require special protection. However, if the
appliance is to be fitted in a timber frame building the guidelines laid
down in BS 5440:Part 1:2000 and the gas installer manual Chapter
11, “Gas in Timber Frame Housing” should be adhered to.
The appliances may be installed into an airing cupboard if required.
Use a non-combustible perforated material (max. hole sizes of
13mm) to separate the boiler from the airing space.
Clearances
The minimum clearances shown opposite should be allowed for
installation and servicing, and are also the minimum clearances
required for installation into an unventilated compartment
(see below).
Compartment installation
The appliance may be installed in any room, although particular
attention is drawn to the requirements of the IEE regulations
applicable and in Scotland the electrical provisions with respect to
installation in a room containing a bath or shower.
1. The room in which the appliance is installed does not require a
purpose provided air vent.
2. If the appliance is installed in a cupboard or compartment with
dimensions that allow the minimum clearances shown in the siting
of appliance section above, then no ventilation is required.
Greenstar CDi boilers are exceptional for their number of
additional time saving installation features:
Built-in frost protection for boiler
Built-in fault finding diagnostics
Automatic gas pressure adjustment
Highly versatile multi-directional fluing system
Combined ignition and control board means fewer connections
Pre-fabricated pipes allowing top exit from the boiler
A rigid 22mm compression gas connection eliminating the
need for pre-fabricating the gas pipe onto the isolating valve
The large output range capability of the appliances
7
86 14
Wall preparation
The drawing shows the CDi
Conventional wall mounting jig
which enables a simple and
straightforward method of attaching
the boiler to the wall surface.
After fixing the jig to the wall, the
appliance can be lifted onto the
jig and the union connections
tightened. The pipe work can be
routed behind the boiler without the
need for an additional wall spacing
frame.
Condensate disposal
All condensing boilers generate condensate discharge which needs
to be piped away from the appliance via a plastic pipe.
The amount of condensate generated depends on the efficiency
and operating status of the appliance. This can be up to 2 litres of
condensate water an hour.
12
2
11
5
4
3
1
10
13
9
BBT181 Gstr CDi Conv T&S IssB 4/5/06 11:21 Page 8