Vue de la page 14
PRE -
INSTALLATION
FLUE OPTIONS
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR Ri
8 716 115 168a (06/2008)
13
Maximum telescopic flue length
100mmØ 125mmØ
12 Ri 570mm 1,070mm
15 Ri 570mm 1,070mm
18 Ri 570mm 1,070mm
24 Ri 570mm 1,070mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 4,600mm 13,000mm
15 Ri 4,600mm 13,000mm
18 Ri 4,600mm 13,000mm
24 Ri 4,600mm 13,000mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 4,600mm 13,000mm
15 Ri 4,600mm 13,000mm
18 Ri 4,600mm 13,000mm
24 Ri 4,600mm 13,000mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 2,600mm 11,000mm
15 Ri 2,600mm 11,000mm
18 Ri 2,600mm 11,000mm
24 Ri 2,600mm 11,000mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 2,600mm 11,000mm
15 Ri 2,600mm 11,000mm
18 Ri 2,600mm 11,000mm
24 Ri 2,600mm 11,000mm
Maximum total flue length
100mm‚Ø 125mmØ
12 Ri N/A 9,000mm
15 Ri N/A 9,000mm
18 Ri N/A 9,000mm
24 Ri N/A 9,000mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 6,400mm 15,000mm
15 Ri 6,400mm 15,000mm
18 Ri 6,400mm 15,000mm
24 Ri 6,400mm 15,000mm
Maximum total flue length
100mm‚Ø 125mmØ
12 Ri 4,400mm 13,000mm
15 Ri 4,400mm 13,000mm
18 Ri 4,400mm 13,000mm
24 Ri 4,400mm 13,000mm
Maximum total flue length
100mmØ 125mmØ
12 Ri 2,400mm 11,000mm
15 Ri 2,400mm 11,000mm
18 Ri 2,400mm 11,000mm
24 Ri 2,400mm 11,000mm
The Greenstar series has the option of two horizontal RSF (60/100 telescopic and
80/125) flue systems and two vertical RSF (60/100 or 80/125) flue systems:
The systems have different maximum flue lengths
This page shows various fluing options with the straight flue lengths required to
achieve the maximum flue length. Note that:
each 90° bend used is equivalent to 2 metres of straight flue
each 45° bend used is equivalent to 1 metre of straight flue
NOTE: Plume management kits are available for the 60/100 horizontal flue option.
Refer to the manual supplied with the Plume management kits for complete
installation instructions
Telescopic horizontal flue assembly
Horizontal flue extension
High level horizontal flue
Horizontal flue with 2x90° bends
High level horizontal flue with 2x90° bends
High level horizontal flue with 3x90° bends
Vertical balanced flue assembly
Vertical balanced flue system with 2x45° bends
Vertical balanced flue with 2x90° bends
FLUE OPTIONS
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 55 56

Commentaires sur ces manuels

Pas de commentaire