ELECTRICAL WIRING DIAGRAM
1. ST1, Terminal block, 230VAC mains supply.
1a. Control box earth connection.
2. Fuse F1 (T2A, H250V).
3. Boiler mains supply on/off switch.
4. Spark transformer.
5. Flame indicator.
6. ST2, Terminal block for pump & switched live.
7. Transformer connectors.
8. ST5, Fan 230VAC.
9. ST6, Diagnostic interface.
10. Indicator lamp for power supply.
11. ST7, Code plug.
12. S2, Service mode selector switch
13. ST8, No connection.
14. Temperature control and lockout reset.
15. ST9 connector
16. Flame sense electrode,
Pin 1 = green.
17. Primary NTC sensor,
Pin 4 = red, Pin 5 = red.
18. Solenoid valve 1,
Pin 6 = blue, Pin 7 = blue.
19. Solenoid valve 2,
Pin 8 = violet, Pin 9 = violet.
20. Flue overheat sensor,
Pin 11 = orange.
21. High limit stat, (wired in series with flue overheat
sensor & blocked flue protection sensor).
22. Blocked flue protection sensor,
Pin 12 = orange.
23. Fuse F2 (T1.25A, H250V).
7
10
11
12
13
14
22
9
8
5
3
1a
Mains Supply
4
2
15
1617
21
20
19 18
6
PUMP L
PUMP N
BOILER SWITCHED LIVE
1
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR Ri
8 716 115 168a (06/2008)
48
ELECTRICAL WIRING DIAGRAM
FAULT FINDING
& DIAGRAMS